Back to BlogTest & Tag

Damaged Cords and Plugs: Inspection Criteria That Actually Matter

November 9, 20269 min read
Technician inspecting the plug and flexible cord of a portable appliance at a New Zealand workplace

Why cords and plugs are the most common failure point

An appliance can sit on a bench for years and barely be touched, but its cord and plug are handled every single day. They get coiled, tugged, stepped on, dragged across concrete, run over by trolleys and pulled out of the socket by the lead rather than the plug. Over time that handling takes a toll, and the flexible lead and its connections are where a great many electrical faults in portable equipment begin.

That is why a visual check of cords, plugs and tools matters even when a full test is not due. It is the cheapest check available, it takes seconds, and it catches the damage that instruments sometimes will not — the frayed spot, the cracked plug body, the twisted join hidden under heat-shrink.

What the law asks, and where inspection fits

Testing and tagging is not mandatory in New Zealand. No regulation says every appliance must carry a tag, and no authority requires a tag on every cord. The duty sits with the business. Under the Health and Safety at Work Act 2015, a person conducting a business or undertaking must ensure, so far as is reasonably practicable, that the plant and equipment people use is safe. In electrical terms: what is legally required is that equipment is electrically safe and maintained in a safe condition.

Testing and tagging to AS/NZS 3760 is one recognised way of demonstrating that equipment is safe and that a maintenance system is working. It is a standard, not a law, and it is a choice a business makes on risk. WorkSafe New Zealand's guidance is clear on two points that are often lost. First, testing gives a snapshot of how safe an appliance is at the moment it is tested — it does not guarantee the appliance stays safe afterwards. Second, whether or not equipment is tested and tagged, cords, plugs and tools should still be looked at regularly for damage.

For a fuller explanation of the framework, see what is test and tag and the guide to AS/NZS 3760 compliance.

Inspection criteria that actually matter

A useful inspection is not a glance. It is a short, repeatable routine that checks the same points in the same order every time, so nothing is missed when a busy shift is underway.

1. The outer sheath along its whole length

Run your eyes and your hand along the full length of the cord, not just the visible middle. Look for cuts, nicks, abrasion where it rubs against a bench edge, flattening from being trapped under a door, and areas where the sheath has gone soft or shiny. A cord that feels warm, tacky or unusually stiff has been stressed and should be taken out of service for closer inspection.

2. The cord entry at the appliance and at the plug

The point where the cord enters the appliance body, and where it enters the plug, is where bending stress concentrates. A sharp kink, a flattened crush mark, or a gap where the sheath has pulled back to expose inner conductors is a failure point even if the rest of the cord looks fine. This single location accounts for a large share of real-world damage.

3. The plug and its pins

  • Cracks or chips in the plug body, especially around the base of the pins.
  • Bent, loose, discoloured or pitted pins. Discolouration suggests heat, which points to a poor connection or an overloaded outlet.
  • A missing or damaged cover, or a plug that has been taped together.
  • The wrong plug for the environment — an ordinary plug on a lead used outdoors where a weatherproof arrangement is needed.

4. Anchorage and strain relief

A cord must be held so that pulling on the lead is not transmitted to the terminals inside. There should be no movement of the cord where it meets the plug or the appliance. If the cord slides, or you can see inner wires at the entry point, the anchorage has failed.

5. Extension leads, multi-boxes and joins

Extension leads take more abuse than any fixed appliance. Check each socket outlet for looseness, look for taped joins and DIY connectors, and confirm the lead is rated for the load. A domestic multi-board is not the same thing as a compliant portable socket-outlet assembly (PSOA), and on construction work a PSOA must be marked as compliant with AS/NZS 3012 and tested on its own schedule. Extension leads are also a temporary measure, not permanent wiring. More on assessing risk in a workplace is in the electrical risk assessment guide.

A practical visual inspection checklist

Work through these points every time you pick up a piece of portable equipment. The whole check takes well under a minute.

  1. Sheath intact along the entire length — no cuts, abrasion, crushing or soft spots.
  2. No exposed inner conductors at the appliance entry or the plug entry.
  3. Anchorage firm — the cord does not move where it enters the plug or the appliance.
  4. Plug body uncracked and pins straight, clean and free of heat discolouration.
  5. No tape, no repaired plugs and no joins in the lead.
  6. Correct plug and lead for the environment, including outdoor use.
  7. Tag present and readable where the equipment is included in a testing programme.
  8. Any damage found — equipment removed from service immediately.

Colour-coded tags are only useful if you can read them; the meaning of each colour is set out in the guide to test and tag colour codes.

Inspection and testing catch different things

A visual inspection and an instrumented test are complements, not substitutes. Inspection finds mechanical damage you can see: a cut sheath, a cracked plug, a loose anchorage. A test using an appliance tester measures properties you cannot see, such as earth continuity on a Class I appliance and insulation resistance. AS/NZS 3760 combines both. The standard's schedule sets out a visual inspection and, for most equipment, a periodic electrical test, with frequency driven by the type of equipment and the environment it is used in.

Neither step guarantees future safety. Between tests, a cord can be damaged by the next shift. That is why daily or pre-use visual checks carry real weight even where a formal testing programme is in place.

What to do when you find damage

The action is the same regardless of how small the defect looks:

  • Remove the equipment from service immediately. Do not leave a damaged item in circulation with a note attached to it.
  • Make it visibly out of service. Separate it from in-service gear and label it so nobody plugs it back in.
  • Do not attempt your own repair. Taping a damaged sheath, fitting a new plug or re-terminating a lead is repair work that, under the Electricity (Safety) Regulations 2010, has to be carried out by a registered electrical worker. See what happens when equipment fails a test.
  • Repair or replace through a qualified route. A damaged lead can be replaced, or a damaged cord repaired, by someone authorised to do the work, and an appliance that is otherwise sound can often be returned to service cleanly. The cord repair and cord replacement services cover exactly this.
  • Record it. Note what failed, when, and what was done. Patterns in that record tell you which equipment or which part of the site keeps producing failures.

Common mistakes

  • Trusting the tag instead of the cord. A current tag records the condition at the last test, not today. A tagged lead can still be damaged this morning.
  • Taping over damage. Tape hides a defect and lets an unsafe item stay in service.
  • Checking only the middle of the cord. The entries at the plug and the appliance are where damage usually starts.
  • Using extension leads as permanent wiring. Trailing leads get damaged and are not a substitute for fixed outlets.
  • Ignoring heat signs. Discoloured pins or a warm plug mean a connection problem that will get worse.
  • Leaving damaged items in a drawer "for later". If it is not removed from service, it will be used.

Documenting what you find

WorkSafe's guidance recommends documenting results when equipment is tested or inspected, and for construction sites keeping those results available on site. A simple register — what the item is, when it was checked, what was found and what was done — turns ad-hoc checks into a defensible system. If you are setting one up, how to set up a test and tag programme and test and tag record keeping cover the practical mechanics, and the compliance guide is a useful reference to keep on hand.

When to bring in a professional

Visual inspection is something any staff member can and should do before use. What needs care is the electrical test and any repair. If your equipment is on a construction site, in a workshop, on a farm or in another harsh environment, the frequency and scope of testing should reflect that, and a managed programme removes the burden of tracking it yourself. Test and tag services and the construction industry page set out how that works in practice, and questions about your own situation are covered at the FAQs.

The bottom line

Cord and plug inspection is not a substitute for a testing programme, and a testing programme is not a substitute for looking. The two together — routine visual checks by the people using the equipment, supported by periodic testing where your risk assessment calls for it — are what keep damaged leads out of circulation. If a cord is damaged, the job is simple: take it out of service, and let a qualified person deal with it.

Frequently asked questions

cordsplugselectrical safetytest and taginspectionAS/NZS 3760workplace safety