0800 777 230
info@testandtagkiwi.com
What is Test & Tag?

Electrical Safety.
Tested. Tagged. Tracked.

Test & Tag is the process of inspecting, testing, and certifying electrical appliances to ensure workplace safety and regulatory compliance across New Zealand workplaces.

Test and Tag Hero

Why Test & Tag?

Safety isn't optional. It's the law.

Protect People

Prevent electrical injuries and fatalities by ensuring every appliance is safe before use.

Reduce Electrical Hazards

Identify faulty equipment before it causes fires, shocks, or equipment damage.

Meet AS/NZS 3760

Full compliance with the New Zealand standard for in-service inspection and testing.

Digital Compliance

Real-time dashboards, automated reports, and complete audit trails for every asset.

How the Process Works

From inspection to digital compliance.

01

Equipment Identification

Every electrical appliance is identified and logged into the system with a unique asset ID.

02

PAT Testing

Professional testing equipment checks earth continuity, insulation resistance, and polarity.

03

Compliance Tag Applied

A compliant safety tag is attached showing test results, date, and next inspection due.

04

QR Asset Label

A unique QR code links the physical asset to its digital compliance record.

05

Digital Record Created

Full inspection history, technician notes, and compliance status stored securely online.

Core Electrical Tests

Six tests. One standard.

Every appliance undergoes a comprehensive testing sequence as defined by AS/NZS 3760. Each test has a specific purpose to identify electrical faults and improve workplace safety.

Understanding Results

PASS or FAIL. Know instantly.

PASS

Appliance is safe to use

Test and Tag KiwiPASS

Next Test: 12 Jan 2027

  • Safe to use in the workplace
  • Next inspection date clearly marked
  • QR code links to digital record
  • Full compliance documentation

FAIL

Appliance must be removed

Test and Tag KiwiFAIL

Action: Remove

  • Must be removed from service immediately
  • Repair or replace before next use
  • Retesting required after repair
  • Failure documented in compliance system

Specialist Services & Testing

Beyond standard Test & Tag.

In addition to standard portable appliance testing, we provide specialist electrical safety services to cover every compliance requirement in your workplace.

AS/NZS 3760

Inspection & Testing Intervals

Recommended inspection and testing frequencies based on AS/NZS 3760 for different workplace environments and equipment types.

Caution

This information should be read together with the AS/NZS 3760 standard as a whole, particularly Clause 2.1. Inspection intervals vary depending on equipment type and operating environment.

1Factories, workshops, places of work or repair manufacturing, assembly, maintenance or fabrication

Tag: 6 months
RCD Push (P): Daily, or before every use, whichever is the longer
RCD Push (F): 6 months
RCD Time (P): 12 months
RCD Time (F): 12 months

2Environment where the equipment or supply flexible cord is subject to flexing in normal use OR is open to abuse OR is in a hostile environment

Tag: 12 months
RCD Push (P): 3 months
RCD Push (F): 6 months
RCD Time (P): 12 months
RCD Time (F): 12 months

3Environment where the equipment or supply cord is NOT subject to flexing in normal use and is NOT open to abuse and is NOT in a hostile environment

Tag: 5 years
RCD Push (P): 3 months
RCD Push (F): 6 months
RCD Time (P): 2 years
RCD Time (F): 2 years

4Residential type areas of hotels, residential institutions, motels, boarding houses, halls, hostels, accommodation houses, and the like

Tag: 2 years
RCD Push (P): 6 months
RCD Push (F): 6 months
RCD Time (P): 2 years
RCD Time (F): 2 years

5Equipment used for commercial cleaning

Tag: 6 months
RCD Push (P): Daily, or before every use, whichever is the longer
RCD Push (F): NA
RCD Time (P): 6 months
RCD Time (F): NA

6Hire Equipment

Inspection

Tag: Prior to hire
RCD Push (P): Including push-button test by hirer prior to hire
RCD Push (F): NA
RCD Time (P): NA
RCD Time (F): NA

Test and Tag

Tag: 3 months
RCD Push (P): NA
RCD Push (F): NA
RCD Time (P): 3 months
RCD Time (F): 12 months

7Repaired, serviced and second-hand equipment

After repair or service which could affect electrical safety, or on reintroduction to service, refer to AS/NZS 5762

Important Note

Inspection frequencies depend on equipment type, condition, and working environment. Hostile environments require more frequent inspection and testing. Always refer to AS/NZS 3760 or contact our team if you are unsure which interval applies to your workplace.

Digital Compliance

Your compliance, digitally organised.

After every inspection, your results are securely stored and immediately accessible. Real-time dashboards, automated reports, and complete audit trails for every asset across every site.

QR Asset Tracking

Every tested appliance receives a unique QR-coded label. Scan it with any smartphone to instantly view the asset's testing history, compliance status, and next due date.

Learn more

Compliance Reports

Audit-ready reports generated automatically with full asset registers, individual test results, pass/fail summaries, photos of any issues, and recommendations.

Learn more

Customer Portal

Access your complete compliance data 24/7 from any device. View inspection history, download certificates, track upcoming due dates, and manage multiple sites from one dashboard.

Learn more

Photo Evidence

Photos of any issues found during inspection are attached directly to the asset's compliance record, providing clear documentation for your records.

Compliance Certificate

Official documentation confirming your workplace meets AS/NZS 3760 requirements — available for download immediately after testing is complete.

Automated Reminders

Automatic reminders are scheduled before your next inspection is due, so you never miss a compliance deadline or fall out of standard.

Industries

Trusted across every industry.

Construction

3-monthly testing for hostile environments

Mining

High-risk environment compliance testing

Healthcare

Zero disruption to patient care

Schools

Holiday testing with police vetting checks

Universities

Campus and laboratory testing services

Government

Government building compliance testing

Warehousing

Forklift chargers and conveyor systems

Hospitality

Kitchen and front-of-house testing

Retail

Retail store and shopfront compliance

Manufacturing

Plant and machinery electrical testing

FAQ

Common questions.

Ready to Start?

Ready to simplify electrical compliance?

Get a free consultation and discover how Test and Tag Kiwi can keep your workplace safe and compliant.

AS/NZS 3760

Compliant

NZ Wide

Coverage

24hr

Report Turnaround

Digital

Compliance Portal